MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Hole mount
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
6.250 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.625 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.312 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
2.000 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
3.312 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
6.250 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the height.AEBW
Center To Center Distance Between Mounting Facilities Parallel To Height:
4.500 inches
MRC:
The number of actuators provided in the item for selection of switching positions.AFCG
Switch Actuator Quantity:
2
Actuator Height:
0.625 inches
MRC:
Words,letters,numbers,symbols,or any combination thereof,permanently inscribed on the actuator,excluding the part number.AFVE
Actuator Inscription:
Start 1st actuator
MRC:
Words,letters,numbers,symbols,or any combination thereof,permanently inscribed on the actuator,excluding the part number.AFVE
Actuator Inscription:
Stop 2nd actuator
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
600.0 ac and 600.0 dc
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, double throw, double break/double make, permanent jumper, both positions maintained single switch unit
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
200.000 milliamperes resistive dc and 200.000 milliamperes inductive dc and 10.000 amperes resistive ac and 1.200 amperes inductive ac
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
8 screw