부품 정보
Bthis cable assembly has the same fit/form/function as p/n 90-21054-002 it can be relabeled as needed per t.O.1-1a-14 to satisfy the destination andidentification requirements of p/n 90-21054-002
TXT
묘사:
Radio Frequency Cable Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
72.000 feet
MRC:
A measure of the opposition to the flow of electrical current.AAPP
Electrical Resistance:
50.00 ohms impedance
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
0.098 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Solar elec-opti netwk
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Connector plug both ends single conductor
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
1
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
7 single conductor
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded single conductor
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
33 single conductor
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
M39012/55-3026 1st end single conductorm39012/67b0009 2nd end single conductor
MRC:
The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
Terminal Commercial And Government Entity Code:
81349 both ends single conductor
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel core conductor single conductorplastic polytetrafluoroethylene 1st position primary insulation single conductorcopper 2nd position shield braid, metallic single conductorplastic fluorinated ethylene propylene 3rd position jacket single conductor
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Straight