TXT
묘사:
Reciprocating Compressor Unit
MRC:
The number of compressors incorporated in the unit.AAXG
Compressor Quantity:
1
MRC:
The percentage of time for which the item is designed to generate without degradation of rated capacity and discharge pressure.AAXJ
Duty Cycle In Percent:
100
MRC:
The media the machine is designed to compress.AAXK
Gas For Which Designed:
Air
MRC:
The rated capacity of gas delivered by the last stage of compression.AAXL
Discharge Flow Rate:
3.250 cubic feet per minute
MRC:
The gage pressure of gas delivered by the last stage of compression. referred to as condensing pressure for refrigeration compressors.AAXM
Discharge Pressure:
2000.000 pounds per square inch gage
MRC:
The design of the system necessary to maintain the required operating temperature of an item and discharge temperature of the compressed gases.AAXP
Cooling System Design:
Single
MRC:
The cooling medium used to maintain the required operating temperature of the compressed gases.AAXQ
Compressed Gas Cooling Medium:
Air
MRC:
The cooling medium used to maintain the required operating temperature of the compressor.AAXR
Compressor Cooling Medium:
Air
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
The position of the gas cooling equipment whether between stages /intercooler/,after the last stage /aftercooler/,or both.AAXU
Gas Cooling Equipment Type:
Air type aftercooler and air type intercooler
MRC:
The method by which a no load condition is obtained for starting the item.AAXV
Unloader Type:
Manual
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Back pack
MRC:
The reciprocating compressor design as determined by the mechanical action by which compression takes place in the cylinder/s/ of the compressor.AAXY
Reciprocating Compressor Design:
Single acting
MRC:
The number of cylinders incorporated in the item.AAXZ
Cylinder Quantity:
3
MRC:
The style designation indicating the configuration that most nearly corresponds to the angular arrangement of the cylinders.AAYA
Cylinder Arrangement Style:
"w" design
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
3
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Threaded male
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Gasoline engine
MRC:
Indicates the type of control device provided.BDML
Control Device Type:
Automotive speed regulator
MRC:
Indicates the type of safety device(s) provided.BPRZ
Safety Device Type:
Relief valve
MRC:
The brake power required to start and operate the item including all accessories at the actual rated capacity,expressed in unit of power.CXNT
Brake Power Required:
1.5 horsepower
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Flame thrower, portable