MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Bushing mount
MRC:
A measurement of the longest dimension of a bushing,in distinction from width.ABXD
Bushing Length:
0.468 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.562 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.546 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.706 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.AFUQ
Actuator Style:
Round
MRC:
The length of a straight line which passes through the center of the actuator,and terminates at the circumference.AFUR
Actuator Diameter:
0.430 inches
Actuator Height:
1.116 inches
MRC:
The relationship between the actuator position and the actuator action /maintained or momentary/.AFUX
Actuator Position-action Relationship:
Center position maintained and left position maintained and right position maintained
MRC:
The relationship between the actuator position and the integral facility designed to prevent actuator movement.AFUY
Actuator Position-locking Relationship:
Center position no locking action and left position locked out and right position no locking action
MRC:
The hue or tint of the actuator.AFVA
Actuator Color:
White single actuator
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
115.0 ac and 50.0 dc
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded bushing
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, double throw, one position momentary, two positions maintained single switch unit
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
1.000 amperes resistive dc and 3.000 amperes resistive ac and 1.000 amperes inductive ac
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 tab, solder lug