부품 정보
Air data sensor unit rated at -2.5 to +8.5gs, 100 ft/sec to 1.6 indicated mach, all attitudes, 5000 to 50000 ft., sideslip +/-24 deg., angle of attack +40 to -10 deg., pressures measuredin pounds absolute and differential, 0to 20 and 0 to 37 psia, +6 to -6 psid
TXT
묘사:
Pressure Transmitter
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The number of mounting devices used as a means of attaching the item.ACUP
Mounting Device Quantity:
4
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
4.100 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Pressure sensing element
MRC:
The number of contacts which provide electrical connection.AFRA
Contact Quantity:
15
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
P4B/-BX-ACT-SPOD
MRC:
Indicates the type of contact(s) included on the item.AKSF
Contact Type:
Pin
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
Air data sensor computes calibrated airspeed, true airspeed, mach number, angle of attack, and angle of sideslip
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
15.0 volts input
MRC:
The number of electrical connections provided.ASKX
Electrical Connection Quantity:
1
MRC:
The name of the government agency or commercial organization controlling the electrical connection.ASKY
Electrical Connection Controlling Agency:
Cannon or equivalent
MRC:
The identifying number assigned by the government agency or commercial organization controlling the electrical connection.ASKZ
Electrical Connection Identifying Number:
Dam-15p or dama-15p
MRC:
The number of mechanical connections provided.ASSB
Mechanical Connection Quantity:
6
MRC:
Designates the thread size,diameter,or the like,of the mechanical connection.ASSC
Mechanical Connection Size:
0.188 dia.
MRC:
Indicates the type of mechanical connection/s/ provided.ASSD
Mechanical Connection Type:
O-ring sealed hole
MRC:
The means of attaching the item.AXGY
Mounting Method:
Surface
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+20.0 pounds pressure per square inch
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Used with pitot tube p/n 89016191-2