부품 정보
Evacuator surgical wound 48"tube lg 4"wound evacuator needle
TXT
묘사:
Surgical Wound Evacuator
MRC:
The name and number of components which make up the item.ALPC
Component And Quantity:
Needle, 1, perforated tubing, 1, unperforated tubing, 1, y-connector, 1
MRC:
An indication of the disposition of an item after initial use.ANGD
Disposition After Initial Use:
Disposable
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Plastic perforated tubing
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Plastic pump
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Plastic unperforated tubing
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Plastic y-connector
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Steel, corrosion resisting needle err-100 err-100
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Steel, corrosion resisting needle
MRC:
The physical configuration of the chamber.BBDL
Chamber Shape:
Cylindrical
MRC:
The physical configuration of the chamber catch basin.CCWW
Err Default:
Err default
MRC:
The physical configuration of the chamber catch basin.CCWW
Chamber Catch Basin Shape:
Cylindrical
MRC:
The physical configuration of the chamber top section.CCWX
Chamber Top Section Shape:
Circular flat top
MRC:
The length of a straight line which passes through the center of the tubing stem,and terminates at the outside circumference.CCWZ
Tubing Stem Outside Diameter:
0.250 inches
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Disposable; 400.0 ml pump capacity, graduated to 400.0 ml in 25.0 ml increments; 48 in. Lg evacuator tubing; 4 in. Lg wound evacuator needle to make a leakproof fit; used in surgical procedures to evacuate drainage by negative pressure and assist soft tissue, separated by surgery or trauma, to be drawn together
MRC:
A measurement of volume taken by multiplying the length by the width by the height of the unit of issue and rendered in cubic units.SUCB
Unit Of Issue Cube:
0.190 cubic feet
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
D-day item for dod
MRC:
The measured weight of the actual container(s) or supporting device(s) which is in direct contact with the item and its contents.SUWT
Unit Of Issue Weight:
1.30 pounds