부품 정보
Harness, wiring, eplrs power, w1a
TXT
묘사:
Electrical Power Cable Assembly
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Anuyk128v1&2
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Connector 2nd end all conductors
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Connector plug 1st end all conductors
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Connector receptacle 3rd end all conductors
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
2
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the cable assembly.ASQB
Cable Assemblylength:
48.000 inches
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
M55181/4-01 3rd end all conductors
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
M55181/3-01 1st end all conductors
MRC:
The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
Terminal Commercial And Government Entity Code:
81349 1st end all conductors
MRC:
The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
Terminal Commercial And Government Entity Code:
81349 3rd end all conductors
MRC:
A measurement of the longest dimension of an individual conductor,in distinction from width.CXGW
Individual Conductor Length:
43.000 inches 2nd end all conductors
MRC:
A measurement of the longest dimension of an individual conductor,in distinction from width.CXGW
Individual Conductor Length:
5.000 inches 1st end all conductors
MRC:
A measurement of the longest dimension of an individual conductor,in distinction from width.CXGW
Individual Conductor Length:
8.000 inches 3rd end all conductors
MRC:
The number of individual branches extending from the main body of the item.CXQJ
Branch Quantity:
1
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Cap.Protective, heat-skrinkable
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy 101 core conductor single conductor or copper alloy 102 core conductor single conductor
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyvinyl chloride 1st position primary insulation single conductor
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Astmb33 assn standard all material responses core conductor single conductor
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Tin core conductor single conductor
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as type,class,grade,and the like,that identifies the surface treatment material.STDC
Surface Treatment Specification:
Astmb33-63 assn standard single treatment response core conductor single conductor