부품 정보
Weapon system essential
TXT
묘사:
Electrical Fuel Pump
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Nonstandard
MRC:
The number of mounting holes provided.ABTJ
Mounting Hole Quantity:
2
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Electromagnetic
MRC:
An indication of whether or not a feature is included for the item to be operated in a specified depth of water without malfunction.AGEB
Fording Feature:
Not included
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
0.05 gallons per minute
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
2 holes 180.0 degrees apart
MRC:
The spacing between the mounting holes.ALXY
Mounting Hole Spacing:
2.480 in.Min 2.580 in.Max c to c
MRC:
Indicates the type of ground polarity utilized.AXHX
Ground Polarity Type:
Negative
MRC:
An indication of whether or not a vacuum booster is included.BJJC
Vacuum Booster:
Not included
MRC:
An indication of whether or not a fuel filter is included.BJJG
Fuel Filter:
Not included
MRC:
An indication of whether or not a priming lever is included.BJJJ
Priming Lever:
Not included
MRC:
Indicates the type and size of the inlet connection(s) on the item.BJJM
Inlet Connection Type/size:
Fuel 1/4-18 nptf
MRC:
Indicates the type and size of the outlet connection(s) on the item.BJJN
Outlet Connection Type/size:
Fuel 1/4-18 nptf
MRC:
An indication of whether or not a drain facility(ies) is included.BJJP
Drain Facility:
Not included
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
24.0
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead