TXT
묘사:
Power Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not establishednot established
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz single component400.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single componentsingle phase to single phase single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 1.249 inches and 1.249 inches and 1.259 inches 1.259 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
Between 1.058 inches and 1.058 inches and 1.068 inches 1.068 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
Between 1.085 inches and 1.085 inches and 1.095 inches 1.095 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
100.0 degrees celsius100.0 degrees celsius
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosedfully enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal single groupterminal single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 1 primary single component and 3 secondary single component3 secondary single component
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
19.50 ac volts single component 3rd secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
27.42 ac volts single component 1st secondary and 43.40 ac volts single component 1st secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
27.42 ac volts single component 1st secondary and 5.00 ac volts single component single primary and 31.00 ac volts single component single primary and 43.40 ac volts single component 1st secondary52.00 ac volts single component single primary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
42.55 ac volts single component 2nd secondary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
15 wire lead