TXT
묘사:
Rota Electro-mechanical Actuator
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Connector
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Established
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-65.0 degrees fahrenheit and 165.0 degrees fahrenheit
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
7.750 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.950 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
3.380 inches
MRC:
The speed of the drive shaft required to produce the rated capacity of an item,expressed in revolutions per minute.AEQC
Operating Speed At Rated Capacity In Rpm:
79.0
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
C17
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise and counterclockwise
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Gear
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
3.0
MRC:
The measurement of rotation,expressed in degrees.AWQL
Rotation In Deg:
213.5
MRC:
The rated torque of the output drive.AWQM
Output Drive Torque Rating:
50.0 inch-pounds
MRC:
An indication of whether or not a limit switch control is included.AWQN
Limit Switch Control:
Included
MRC:
An indication of whether or not a manual override is included.AWQR
Manual Override:
Not included
MRC:
An indication of the rotation of the angular shaft.AWTZ
Angular Shaft Rotation:
Limited
MRC:
The maximum operating on time and the minimum off time for a complete cycle of an item.AYEK
Intermittent Operation Duty Cycle:
9.0 seconds on and 30.0 seconds off
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Mounting flanges
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
28.0
MRC:
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
Special Test Features:
Fungus method 508.1 procedure i, altitude method 500.1 procedure i, shockmethod 516.2 procedure i, load method 513.2 procedure i
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
00268-mil-std-801 standard (includes industry or association standards, individual manufactureer standards, etc.).