Used on c-17a aircraft
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2a single mounting facility
MRC:
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.AASA
Thread Length:
0.250 inches single mounting facility
Width Between Flats:
0.203 inches single actuator
MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
Explosion proof
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.667 inches
First Flat Length:
0.250 inches single actuator
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.125 inches single actuator
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.750 inches single actuator
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.500 inches
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
1
MRC:
The general configuration of the contacts of a switch that describes its basic switching structure.AJZE
Switch Contact Basic Design:
Nonpile-up symmetrical
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 single section rear
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
3 single section rear
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded bushing single mounting facility
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Metallic inclosure
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.250 inches single mounting facility
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
115.0 ac at sea level28.0 dc at sea level
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
3 single actuator
MRC:
Indicates the type of shaft included on the item.CRSJ
Shaft Type:
Round, parallel flatted single actuator
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Printed circuit
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Breaks before makes single section rear
MRC:
The increments of angular rotation that the switch actuator moves between adjacent index positions.CSLC
Switch Actuator Positioning Increment:
36.0 degrees single actuator
MRC:
The minimum and maximum amount of turning force required to rotate an actuator through the detent positions.CSMW
Detent Rotational Torque Range:
+0.500/+1.500 inch-pounds single actuator
MRC:
Indicates the type of device included in the switch to limit the angular rotation of its actuator.CTDN
Switch Actuator Stop Device Type:
Fixed stop single actuator
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
150.0 milliamperes resistive load ac at sea level30.0 milliamperes inductive load dc at sea level and 100.0 milliamperes lamp load dc at sea level and 200.0 milliamperes inductive load dc at sea level
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Tap, circular, bushing mount
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unf single mounting facility