TXT
묘사:
Power Autotransforme Transformer
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class (non-core):
2a 2nd group
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction (non-core):
Right-hand 2nd group
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.125 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
2.375 inches 1st mounting facili type 1st center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
1.875 inches 1st mounting facili type 1st center group
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.120 inches
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.203 inches 1st group
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single component
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
2 2nd group
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4 1st group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded stud 2nd group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole 1st group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary, fixed autotransformer type single component
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.CBME
Cubic Measure (non-core):
41.4 cubic inches
MRC:
The points between the end terminals of a winding that provide electrical connection to intermediate values of the total winding.CQLC
Winding Tap Location (non-core):
Tap w/o center tap single component single primary output
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
35.7 amperes ac single component single primary output
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
1.0 k1lovolt-amperes single component single primary output
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
11.00 ac pounds per hour wet single component single primary output and 28.00 ac pounds per hour wet single component single primary output
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
117.00 ac pounds per hour wet single component single primary input
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 threaded stud