TXT
묘사:
Radio Frequency Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
26 single component 1st secondary27 single component 2nd secondary27 single component 3rd secondary27 single component 4th secondary7 single component single primary
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
0.50 microhenries single component 1st secondary2.72 microhenries single component 2nd secondary2.72 microhenries single component 3rd secondary24.50 microhenries single component 4th secondary0.60 microhenries single component single primary
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
100.0 kilohertz single component
MRC:
Indicates the type of support on which the coil is wound.ACZP
Coil Form Type:
Solid single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.202 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
1.120 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component single primary and winding turns single component single primaryelectrical single component all secondary and winding turns single component all secondary
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 4 secondary single component
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.01594 inches american wire gage single component 1st secondary0.01420 inches american wire gage single component 2nd secondary0.01420 inches american wire gage single component 3rd secondary0.01420 inches american wire gage single component 4th secondary0.01594 inches american wire gage single component single primary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
10 pin