MRC:
A recording of the physical,functional,and performance characteristics for an item of supply.TEXT
General Description:
Lmeets ul grade aa line security requirements; meets diam 50-3 class "b" line security; meets class "a" with optional des encryptor; sensitivi type 0 - 5v; operating temp -30to 70c; shock 8g for 11 msec positive and negative; humidi type 95%; vibration 4 - 5hz random; data i/o 2 fiber ports1 rs-422 port; range 2.25km for fiber optics, 2.25km for rs-422; dual fiber optic ports 50, 62.5 or 100 micron fiber, type st connectors; sensor inputs: 8 eol supervised (class "b") user adjustable eolr value (2.2k ohm typ); relay outputs: 4 form a, programmable n.O. Or n.C.; .05a at 115vac, or 2a at 24vdc; 3 buss led status indicators; power 9 to 24vdc at400ma max; transient suppression: 1mw protection on power inputs and electrical busses