MRC:
The ability of an item to withstand a specified torque load without fracture.AAPL
Torque Load Rating:
7.50 inch-ounces
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.875 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.969 inches
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four no. 4-40 thd mtg holes spaced on 1.359 in. By 1.000 in. Mtg centers
MRC:
The basic structure of the item.ALXF
Structural Design:
Sectional
MRC:
The value/s/ of direct current potential which must be applied to the item for operation,expressed in volts.APBR
Dc Operating Voltage Rating In Volts:
Between 20.0 and 32.0
MRC:
The specific number of contact terminals included.APNG
Contact Terminal Quantity:
1
MRC:
The specific number of coil terminals included.APNH
Coil Terminal Quantity:
2
MRC:
The specific number of common terminals included.APNJ
Common Terminal Quantity:
1
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Not provided
MRC:
The amount of current required to activate the item.AXAZ
Pull-in Current:
3.7 amperes
MRC:
The amount of current required to maintain operation of the item.AXBA
Hold-in Current:
10.5 milliamperes
MRC:
The direction of rotation for which the item is designed.AYSY
Rotation Direction For Which Designed:
Counterclockwise
MRC:
The number of sections included.BWGP
Section Quantity:
1
MRC:
The number of coil winding(s) provided.CPWL
Coil Winding Quantity:
1
MRC:
An indication of the characteristic(s) of a winding.CPWM
Winding Characteristic:
Single wound tapped
MRC:
The amount of direct current resistance required to activate the coil pull-in.CPWP
Coil Pull-in Dc Resistance Rating:
7.5 ohms
MRC:
The amount of direct current resistance required to maintain operation of the coil hold-in.CPWQ
Coil Hold-in Dc Resistance Rating:
260.0 ohms