MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
13.750 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
9.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.250 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Metal
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
Case Surface Treatment:
Enamel, gray
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Audio and glow lamp and meter
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Gamma rays detects
MRC:
Indicates the type of detecting element included.AMRX
Detecting Element Type:
Solid state
MRC:
An indication of whether or not the item is portable.APCB
Portability:
Nonportable
MRC:
The minimum and maximum amount of radiation detected per hour.APPJ
Radiation Range Per Hour:
+0.1/+100.0 milliroentgens
MRC:
The minimum and maximum amount of radiation detected per hour.APPJ
Radiation Range Per Hour:
+0.1 to 100.0 milliroentgens
MRC:
The minimum and maximum number of single responses per minute.APPK
Count Range Per Minute:
Not rated
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-15.0/+15.0 at full scale
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-15.0 to 15.0 at full scale
MRC:
The value of electrical potential to which an item will respond.APPP
Input Sensitivity Voltage Rating:
Not rated
MRC:
An indication of the energy dependence rating of the item.APPQ
Energy Dependence Rating:
+0.080/+2.000 mev
MRC:
An indication of the energy dependence rating of the item.APPQ
Energy Dependence Rating:
+0.080 to 2.000 mev
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
115.0 ac
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0