부품 정보
Measurement range contd: single indicator, 17 range m199.9/p199.9 millivolts; 18 range p0.0/p199.9 ohms; 19 range p0.0/p1.9 acv; 20 range p0.0/p19.9 acv; 21 range p0.0/p199.9 acv; 22 range p0.0/p750.0 acv; 23 range m1.9/p1.9 dcv; 24 range m19.9/p19.9 dcv; 25 range m199.9/p199.9 dcv; 26 range m1100.0/p1100.0 dcv
MRC:
The maximum voltage the insulating materials of the item will withstand without resulting in disruptive discharge or deterioration,expressed in volts.AAPB
Dielectric Withstanding Voltage In Volts:
1100.0
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
5.700 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.900 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 48.000 hertz and 66.000 hertz
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Rechargeable battery 4, battery charger/eleminator 1, test lead 2
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
Internal
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1.9 kilohms single indicator 1st range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1.9 milliamperes, ac single indicator 8th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+19.9 kilohms single indicator 2nd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+19.9 megohms single indicator 5th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+19.9 milliamperes, ac single indicator 9th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+199.0 kilohms single indicator 3rd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+199.9 microamperes, ac single indicator 6th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+199.9 milliamperes, ac single indicator 10th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+199.9 millivolts, ac single indicator 16th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1999.9 kilohms single indicator 4th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1999.9 milliamperes, ac single indicator 11th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-1.9/+1.9 milliamperes, dc single indicator 12th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-19.9/+19.9 milliamperes, dc single indicator 13th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-199.9/+199.9 microamperes, dc single indicator 7th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-199.9/+199.9 milliamperes, dc single indicator 14th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-1999.9/+1999.9 milliamperes, dc single indicator 15th range
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Electrical overload protection
MRC:
The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
Operating Voltage Rating In Volts:
6.0 dc
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
D1 rectangular or square