부품 정보
Isolation 10.0 db; vswr 2.00; rf connectors female; 20.0 volt pulse
TXT
묘사:
Radio Frequency Amplifier
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 5.490 inches and 5.510 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.750 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Moisture proof
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
+10.0/+55.0
MRC:
The amplitude of vibration for which the vibration resistance frequency range applies.AFDN
Vibration Resistance Amplitude:
0.1 inches total excursion
MRC:
The maximum force at impact that the item is rated to withstand,without resulting in any permanent change in physical or electrical characteristics,expressed in gravitational units /g's/.AFDP
Shock Resistance Rating In Gravitational Units:
15.0
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+70.0 degrees celsius
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/alr-20a
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
65000.0 feet
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Automatic
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Mechanical
MRC:
Indicates the type of control.AQZF
Control Type:
Local
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
50.0 megahertz operating channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
500.0 megahertz operating channel err-100
MRC:
The amount of allowable variation relative to a specified frequency level,expressed in decibels.BHTG
Variation Frequency Rating In Decibels:
20.0
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
75.0
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
30.0 watts input
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
120.000 volts input
MRC:
The increase in energy from the input to the output.BHTL
Overall Gain:
42.0 decibels
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 ohms operating channel
MRC:
Indicates the type of distortion and its percent.BJBG
Distortion Type And Percent:
6.0 frequency
MRC:
The maximum time an item will continuously run,expressed in hours.BJBM
Maximum Continuous Operating Time In Hours:
10000.0
MRC:
The length of time after impact that established the condition at which the shock resistance rating applies.BJBN
Shock Pulse Duration Time:
1.0 milliseconds
MRC:
Indicates the type of connection and its location on the item.BJBP
Connection Type And Location:
Single panel jack left side and single panel jack right side
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
400.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
An/alr-20a, generic nsn