TXT
묘사:
Centrifugal Pump Unit
MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Base
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
2
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Unthreaded external
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
2
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Unthreaded external
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Liquid
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
2
MRC:
The means of cooling used to maintain the required operating temperature of the item.AENK
Cooling Method:
Air to air cooled
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
6.7 gallons per minute and 6.7 gallons per minute
MRC:
The sum of the total discharge head and the total suction lift.AHYX
Total Head:
16.100 feet
MRC:
The speed of the item required to produce its rated capacity.AHYZ
Operating Speed At Rated Capacity:
3450.0 revolutions per minute
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Horizontal
MRC:
The design of a centrifugal pump as determined by the direction of media flow with respect to the axis of the shaft.AHZE
Centrifugal Pump Design:
Axial flow
MRC:
The number of impellers incorporated in the centrifugal pump.AHZF
Centrifugal Pump Impeller Quantity:
2
MRC:
Indicates the type of suction produced by the impeller of the centrifugal pump.AHZG
Centrifugal Pump Impeller Suction Type:
Single
MRC:
Indicates the type of device used to control the output or capacity of an item.AHZP
Volume Control Type:
Rotary
MRC:
Indicates the location of the control on the item.AHZQ
Control Location:
Center
MRC:
An indication of how the items are designed to operate in relation to each other.AHZS
Operation Relationship Design:
Simultaneous
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
0.8
MRC:
The rated power of the prime mover.CSYL
Prime Mover Power Rating:
0.125 horsepower
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
230.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 and 60.0