TXT
묘사:
Radio Frequency Cable Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
9.250 inches
MRC:
A measure of the opposition to the flow of electrical current.AAPP
Electrical Resistance:
93.00 ohms impedance
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
0.242 inches
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Stripped 2nd end single conductor
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Connector plug 1st end single conductor
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
1
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Solid single conductor
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
22 awg single conductor
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
1 coaxial
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
8177521 1st end single conductor
MRC:
The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
Terminal Commercial And Government Entity Code:
18876 1st end single conductor
MRC:
A measurement of the longest dimension of an individual conductor,in distinction from width.CXGW
Individual Conductor Length:
0.500 inches 2nd end single conductor
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
L-p-390, type 2, class l, grade 4 federal specification single material response 1st position primary insulation single conductor
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Qq-w-343, soft federal specification all material responses 6th position primary insulation single conductor
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Qq-w-345 federal specification all material responses 1st position conductor single conductor
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Internal connector and stripped