부품 정보
						Front panel controls:  prime power on/off, rf operate/standby (fault reset). Front panel indicators:  prime power on/standby, rf operate, fault. Metering:  helix current. Protection:  prime power fuse, warm up delay, automatic sequencing of high voltage and beam current, unattended protection (heater shutdown after fault counter trip), helix current overload, high temperature low/high line voltage, safety interlocks. Equipment case, is a self-contained designed for bench top or rack mount. Auto recycle if power outage is lessthan 3 seconds. Automatic turn off if two consecutive helix overload faults occur: noise figure 35db max:  spurious modulation m50dbc max:  load vswr 2.5: 1 max:  gain stabili type 0.25db/24hrs:  maxoperating humidi type 95pct
					 
				 
						
			
				
					TXT
				
				
					묘사:
				
				
					Radio Frequency Amplifier				
			 
			
							
										
					
						MRC:
						The element,compound,or mixture of which the inclosure is fabricated,excluding any surface treatment.ABBH
					 
					
						Inclosure Material:
					
					
						Aluminum					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						21.240 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						3.500 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						18.240 inches 					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						+0.0/+50.0 degrees celsius					
				 
							
					
						MRC:
						A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.AFJK
					 
					
						Cubic Measure:
					
					
						0.733 cubic feet					
				 
							
					
						MRC:
						A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
					 
					
						Average Life Measurement:
					
					
						Not rated					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
					 
					
						Basic Shape Style:
					
					
						Rectangular or square					
				 
							
					
						MRC:
						The maximum altitude at which the item is rated to function.AKAE
					 
					
						Maximum Operating Altitude Rating:
					
					
						10000.0 feet					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encased					
				 
							
					
						MRC:
						The means by which the item is operated or controlled.ALBM
					 
					
						Operating Control Method:
					
					
						Manual					
				 
							
					
						MRC:
						The installation for which the item is designed.AMQY
					 
					
						Installation Design:
					
					
						Top of cabinet/counter and rack					
				 
							
					
						MRC:
						Indicates the type of control.AQZF
					 
					
						Control Type:
					
					
						Local					
				 
							
					
						MRC:
						Indicates the type of circuit construction provided in the item.BHSX
					 
					
						Circuit Construction Type:
					
					
						Solid state					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						4.0 gigahertz  operating channel err-100 and 8.0 gigahertz  operating channel err-100					
				 
							
					
						MRC:
						The rated average power for each channel.BHTJ
					 
					
						Average Power Rating Per Channel:
					
					
						10.0 watts output					
				 
							
					
						MRC:
						The increase in energy from the input to the output.BHTL
					 
					
						Overall Gain:
					
					
						30.0 decibels					
				 
							
					
						MRC:
						Indicates the type of connection and its location on the item.BJBP
					 
					
						Connection Type And Location:
					
					
						Receptacle,  coaxial front					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the operating alternating current.BJBQ
					 
					
						Operating Ac Frequency In Hertz:
					
					
						47.0  single voltage and 63.0  single voltage					
				 
							
					
						MRC:
						The maximum power drain for which the item is rated.BJBR
					 
					
						Maximum Power Drain Rating:
					
					
						250.0 watts					
				 
							
					
						MRC:
						Indicates the type and number of contact(s) included in the connection.BJBW
					 
					
						Connection Contact Type And Quantity:
					
					
						1 receptacle,  coaxial internal					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
					 
					
						External Ac Operating Voltage In Volts:
					
					
						99.0  single voltage and 132.0  single voltage					
				 
							
					
						MRC:
						The number of alternating current phases.FAAZ
					 
					
						Phase:
					
					
						Single					
				 
							
					
						MRC:
						Indicates the relationship,such as construction,capabilities,and the like,of the item to a similar item.RTSE
					 
					
						Relationship To Similar Equipment:
					
					
						6625-01-034-6118