TXT
묘사:
Tachometer Generator
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise single end or counterclockwise single end
MRC:
The means of attaching the item.AXGY
Mounting Method:
Face
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
3 threaded hole
MRC:
The acceptable limits of deviation from the designed standard output value of the item,expressed in percent.BDJD
Accuracy Range In Percent:
-0.1/+0.1
MRC:
The speed at which the calibration is determined,expressed in revolutions per minute.BFLQ
Calibration Speed In Rpm:
1000.0
MRC:
An indication of the type of calibration voltage output,expressed in volts.BKPC
Calibration Voltage Output Type In Volts:
7.0 dc
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Horizontal mounting position and vertical mounting position
MRC:
The length of a straight line which passes through the center of a mounting facility circle,and terminates at the circumference.CWFQ
Mounting Facility Circle Diameter:
0.875 inches
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A6 single style single end
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 solder lug