TXT
묘사:
El Engine Starter Relay-solenoid
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.272 inches
MRC:
The nominal value(s) of potential for which the item is rated.AWYG
Voltage Rating:
24.0 volts
MRC:
The voltage rating at which the item will close.AWZB
Closing Voltage Rating:
24.0 volts
MRC:
The amount of current required to maintain operation of the item.AXBA
Hold-in Current:
7.3 amperes
MRC:
The measured distance of the plunger stroke.AXBD
Plunger Stroke Length:
0.620 inches
MRC:
An indication of whether or not engaging linkage is included.AXBE
Engaging Linkage:
Not included
MRC:
Designates the thread diameter and number of threads per measurement scale of the accommodated linkage threaded hole.AXBY
Accommodated Linkage Threaded Hole Thread Size:
3/8-24
MRC:
An indication of whether or not the item includes provisions for manually closing the contacts.AXCC
Contact Manual Closing Provision:
Included
MRC:
The number of control terminals provided.AXCD
Control Terminal Quantity:
2
MRC:
Indicates the type of control terminal/s/ provided.AXCE
Control Terminal Type:
Threaded stud
MRC:
An indication of whether or not a grounded control terminal is included.AXCF
Grounded Control Terminal:
Not included
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 hole