TXT
				
				
					묘사:
				
				
					Fluid Pressure Regulating Valve				
			 
			
										
					
						MRC:
						The basic material of which the body is fabricated.AAFZ
					 
					
						Body Material:
					
					
						Brass					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Straight thru					
				 
							
					
						MRC:
						The element, compound,or mixture of which the stem is fabricated,excluding any surface treatment.ABEP
					 
					
						Stem Material:
					
					
						Steel					
				 
							
					
						MRC:
						Items furnished as accessories which are not specified elsewhere.ABFF
					 
					
						Furnished Items:
					
					
						Cylinder gage and delivery gage					
				 
							
					
						MRC:
						The type of service with which the item is designed to be used.ACKL
					 
					
						Media For Which Designed:
					
					
						Argon and helium					
				 
							
					
						MRC:
						A narrative description of the type of end connection.ACKM
					 
					
						First End Connection Type:
					
					
						Threaded external tube					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
					 
					
						First End Style Designator:
					
					
						Inverted flare					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACLH
					 
					
						First End Outside Diameter Tube Accommodated:
					
					
						0.375 inches 					
				 
							
					
						MRC:
						Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACLJ
					 
					
						First End Thread Size And Series/type Designator:
					
					
						0.563-18 unf					
				 
							
					
						MRC:
						A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.ACLK
					 
					
						First End Thread Class:
					
					
						2a					
				 
							
					
						MRC:
						The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
					 
					
						First End Thread Direction:
					
					
						Right-hand					
				 
							
					
						MRC:
						Indicates whether or not the second end is identical to the first end.ACLR
					 
					
						Second End Relationship With First End:
					
					
						Not identical					
				 
							
					
						MRC:
						A narrative description of the type of end connection.ACLS
					 
					
						Second End Connection Type:
					
					
						Threaded external gas cylinder					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACLT
					 
					
						Second End Style Designator:
					
					
						Swivel nut,  flared					
				 
							
					
						MRC:
						Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACMQ
					 
					
						Second End Thread Size And Series/type Designator:
					
					
						0.965-14 ngo					
				 
							
					
						MRC:
						The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACMS
					 
					
						Second End Thread Direction:
					
					
						Right-hand					
				 
							
					
						MRC:
						The angle of the end surface upon which the mated surface seats,expressed in degrees.ACTE
					 
					
						First End Seat Angle In Deg:
					
					
						30.0					
				 
							
					
						MRC:
						The part that controls the flow through the item.ADQU
					 
					
						Flow Control Device:
					
					
						Poppet					
				 
							
					
						MRC:
						The element,compound,or mixture of which the flow control device is fabricated.ADQV
					 
					
						Flow Control Device Material:
					
					
						Steel,  corrosion resisting					
				 
							
					
						MRC:
						The number of end connections included in the item.ADQZ
					 
					
						End Connection Quantity:
					
					
						2					
				 
							
					
						MRC:
						The minimum to maximum limits of outlet pressure of the item.AEVA
					 
					
						Outlet Pressure Range:
					
					
						+0.0 to 400.0 pounds per square inch					
				 
							
					
						MRC:
						Indicates the basic design type used for regulating the item.AEVN
					 
					
						Regulation Type:
					
					
						1st stage manual,  2nd stage automatic					
				 
							
					
						MRC:
						The means used to manually adjust the item.AEVP
					 
					
						Manual Control Method:
					
					
						Tee handle					
				 
							
					
						MRC:
						The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
					 
					
						Valve Loading Method:
					
					
						Spring					
				 
							
					
						MRC:
						The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
					 
					
						Maximum Inlet Pressure Rating:
					
					
						3000.0 pounds per square inch					
				 
							
					
						MRC:
						An indication of whether or not a filter is included.AEWF
					 
					
						Filter:
					
					
						Included