TXT
묘사:
Variable Attenuator
MRC:
The primary application for which the item is designed.AAFS
Application Design:
Transmission line
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Coaxial type
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.703 inches
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.20 and 1.30 and 1.50
MRC:
The means by which the attenuation can be varied from the minimum to the maximum setting.ASYF
Attenuation Variation Method:
Stepped
MRC:
The number of intervals at which the item can be set.ASYG
Step Position Quantity:
12
MRC:
The amount of attenuation between adjacent steps,expressed in decibels.ASYH
Attenuation Per Step In Decibels:
1.0
MRC:
Indicates the type and number of facilities for adjusting the item.CQTQ
Adjustment Device Type And Quantity:
1 knob
MRC:
The total opposition (resistive and reactive) to the flow of alternating current,expressed in ohms.CTGG
Impedance Rating In Ohms:
50.0 input-output
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 connector, coaxial, female