					묘사:
				
				
					Waveguide Assembly				
			 
			
										
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
					 
					
						Cross Sectional Shape:
					
					
						Internal,  rectangular external,  rectangular					
				 
							
					
						MRC:
						A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
					 
					
						Thread Class:
					
					
						2a second flange all connection facilities					
				 
							
					
						MRC:
						The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
					 
					
						Thread Direction:
					
					
						Right-hand second flange all connection facilities					
				 
							
					
						MRC:
						The angular measurement by which one part/section of a rigid item deviates from a straight line projection of an adjacent part/section,expressed in degrees.ACJL
					 
					
						Bend Angle In Deg:
					
					
						180.0 all bends e-plane					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the construction of the tubing wall.AHRV
					 
					
						Tubing Wall Construction Style:
					
					
						Seamless single tubing segment					
				 
							
					
						MRC:
						The number of flanges provided with the item.AHSF
					 
					
						Flange Quantity:
					
					
						2					
				 
							
					
					
						Flange Inside Width:
					
					
						1.122 inches  first flange					
				 
							
					
					
						Flange Inside Width:
					
					
						1.312 inches  second flange					
				 
							
					
					
						Flange Inside Height:
					
					
						0.497 inches  first flange					
				 
							
					
					
						Flange Inside Height:
					
					
						0.628 inches  second flange					
				 
							
					
					
						Flange Outside Width:
					
					
						1.875 inches  first flange					
				 
							
					
					
						Flange Outside Width:
					
					
						1.875 inches  second flange					
				 
							
					
					
						Flange Outside Height:
					
					
						1.875 inches  first flange					
				 
							
					
					
						Flange Outside Height:
					
					
						1.875 inches  second flange					
				 
							
					
					
						Flange Inside Diameter:
					
					
						1.253 inches  first flange					
				 
							
					
						MRC:
						A measurement between specified points on the flange,in distinction from height.AHTD
					 
					
						Flange Depth:
					
					
						0.437 inches  second flange					
				 
							
					
						MRC:
						A measurement between specified points on the flange,in distinction from height.AHTD
					 
					
						Flange Depth:
					
					
						0.625 inches  first flange					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
					 
					
						Flange Connecting Hole Diameter:
					
					
						0.169 inches  first flange all connection facilities					
				 
							
					
						MRC:
						The maximum pressure at which the item is rated for operation.CQGM
					 
					
						Maximum Operating Pressure:
					
					
						25.0 pounds per square inch gage					
				 
							
					
					
						Waveguide Outside Width:
					
					
						1.250 inches 					
				 
							
					
						MRC:
						A designation that is used for the purpose of general identification of the thread.CQJX
					 
					
						Thread Size:
					
					
						0.164 inches second flange all connection facilities					
				 
							
					
					
						Waveguide Inside Width:
					
					
						1.122 inches 					
				 
							
					
					
						Waveguide Inside Height:
					
					
						0.497 inches 					
				 
							
					
					
						Waveguide Outside Height:
					
					
						0.625 inches 					
				 
							
					
						MRC:
						The type and number of facilities by which the flange is connected.CSQT
					 
					
						Flange Connecting Facility And Quantity:
					
					
						4 threaded hole second flange all connection facilities					
				 
							
					
						MRC:
						The type and number of facilities by which the flange is connected.CSQT
					 
					
						Flange Connecting Facility And Quantity:
					
					
						4 unthreaded hole first flange all connection facilities					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
					 
					
						Flange Style:
					
					
						Choke type first flange					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
					 
					
						Flange Style:
					
					
						Cover type second flange					
				 
							
					
					
						Waveguide Length:
					
					
						17.125 inches 					
				 
							
					
					
						Waveguide Center To Center Distance:
					
					
						9.610 inches 					
				 
							
					
						MRC:
						Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
					 
					
						Flexibility:
					
					
						Rigid single tubing segment					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Aluminum alloy all flange					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Offset bend type					
				 
							
					
						MRC:
						A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
					 
					
						Thread Series Designator:
					
					
						Unc second flange all connection facilities