TXT
묘사:
Power Autotransforme Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
4.600 inches single mounting facility single center group and 4.640 inches single mounting facility single center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
4.600 inches single mounting facility single center group and 4.640 inches single mounting facility single center group
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.204 inches single group
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 4.000 inches and 4.040 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
Between 5.100 inches and 5.140 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary, fixed autotransformer type single component
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
41.50 ac volts single component single primary output and 43.00 ac volts single component single primary output and 44.50 ac volts single component single primary output and 46.50 ac volts single component single primary output and 48.50 ac volts single component single primary output and 50.50 ac volts single component single primary output and 52.50 ac volts single component single primary output and 54.50 ac volts single component single primary output and 56.50 ac volts single component single primary output and 59.00 ac volts single component single primary output and 61.00 ac volts single component single primary output and 63.50 ac volts single component single primary output and 66.00 ac volts single component single primary output
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
68.50 ac volts single component single primary input
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
15 threaded stud