부품 번호 7621K5

Signal Data Recorder

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards
부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
7621k5
비무장화:
No
수명:
측정 단위:
NIIN:
014213501

부품 정보
Unit can display 44 separate functions including present peak, time of peak, readings, time of , readings, time of , average readings, sweep of present readings, and total time; three clamp on current transducers measure circuits up to 3-phase; auto-ranging finds proper range; computer retains memory in case of power loss; in record mode the unit monitors 9 readings while simultaneously in sweep mode; measures to 1000 vac with accuracy porm 1.5 pct of reading; to 750 vac with accuracy porm 1.0 pct of reading

NSN
국가 주식 번호:
6625-01-421-3501 6625014213501
TXT
묘사:
Signal Data Recorder
INC
INC
아이템 이름 코드:
21118
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
13.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
10.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
Between 120.0 volts and 440.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/tp (v) series radar sets; nha is pressure dehydrator
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included
MRC:
The means by which the item records information.ANBK
Recording Method:
Any acceptable
MRC:
Indicates the type of information the item will record.ARYS
Information Recorded:
True rms current & voltage & peak current data from 6 inputs
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Battery pack requires 4 "c" batteries; a switch selects ac and power; transducers, leads, and jacks are colorcoded to help prevent hook-up errors

{lang[cimilar]} Signal Data Recorders

« Electrical and Electronic Properties Measuring and Testing Instruments {lang[catalog]}
지금 비교»
맑다 | 숨기다