TXT
묘사:
Pressurized Cabin Leakage Tester
MRC:
The alpha-numeric designation that identifies the classification of the item according to the category of functions performed.FCLS
Functional Classification:
Aa-8.4
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Supplies pressurized air for performance checking under pressurized conditions
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
T.O. 33d2-28-10-1 and mil-t-26141
MRC:
A recording of the physical,functional,and performance characteristics for an item of supply.TEXT
General Description:
Portable, self-contained; gasoline-engine-driven unit; 10 to 400 cubic ft per minute (cfm), 2 to 12.5 lb per square in. (psi); components: canopy seal system; pressurization system; measuring system; trailer; control panel; housing; accessory box; pressurization hose storage device; accessories; one an6270-8-300 hose, dust caps; one an6270-6-300 hose, dust caps; one an893-12d bushing; one an893-2d bushing; setof adapters and gasket; 25 ft, 3.000 in. Inside dim. Air hose; stethoscope; performance: operating temperatures ranging from -20 degree to +120 degree f.
MRC:
The alpha-numeric-alpha designation used to identify the type and/or model of the basic item.TMDN
Type/model Designation:
Af/m32t-1