TXT
묘사:
Pressure Transmitter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.078 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of mounting devices used as a means of attaching the item.ACUP
Mounting Device Quantity:
4
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz input
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
2.141 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Bourdon tube
MRC:
The number of contacts which provide electrical connection.AFRA
Contact Quantity:
4
MRC:
Indicates the type of contact(s) included on the item.AKSF
Contact Type:
Pin
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
Designed to transmit the indicated pressure in the fuel system of aircraft engines
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
26.0 volts input
MRC:
The number of electrical connections provided.ASKX
Electrical Connection Quantity:
1
MRC:
The name of the government agency or commercial organization controlling the electrical connection.ASKY
Electrical Connection Controlling Agency:
And
MRC:
The identifying number assigned by the government agency or commercial organization controlling the electrical connection.ASKZ
Electrical Connection Identifying Number:
Part no. And10066-14s-2p
MRC:
The number of mechanical connections provided.ASSB
Mechanical Connection Quantity:
2
MRC:
Designates the thread size,diameter,or the like,of the mechanical connection.ASSC
Mechanical Connection Size:
7/16 in. Dia
MRC:
Indicates the type of mechanical connection/s/ provided.ASSD
Mechanical Connection Type:
Internal pipe
MRC:
The means of attaching the item.AXGY
Mounting Method:
Hole
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.000/+500.000 pounds per square inch
MRC:
The number of alternating current phases.FAAZ
Phase:
Single input
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
E-2 type
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Engine instrument, acft