MRC:
						A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
					 
					
						Thread Class:
					
					
						3b first threaded hole					
				 
							
					
						MRC:
						A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
					 
					
						Thread Class:
					
					
						3b second threaded hole					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						3.891 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						5.312 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						5.250 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						2.375 inches 					
				 
							
					
						MRC:
						The longest distance between mounting centers parallel to the horizontal plane.AFDS
					 
					
						Longest Horizontal Distance Between Mounting Centers:
					
					
						2.000 inches 					
				 
							
					
						MRC:
						The longest distance between mounting centers parallel to the vertical plane.AFDV
					 
					
						Longest Vertical Distance Between Mounting Centers:
					
					
						2.625 inches 					
				 
							
					
						MRC:
						The general classification of a pressure switch based on the reference method used to measure the sensed pressure.AJZC
					 
					
						Pressure Switch Type:
					
					
						Gage					
				 
							
					
						MRC:
						The temperature at which the item operates.AWTN
					 
					
						Operating Tempurature Rating:
					
					
						Between -65.0 degrees fahrenheit and 160.0 degrees fahrenheit 					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Flange					
				 
							
					
						MRC:
						The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
					 
					
						Thready Qty Per Inch (tpi):
					
					
						20 first threaded hole					
				 
							
					
						MRC:
						The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
					 
					
						Thready Qty Per Inch (tpi):
					
					
						20 second threaded hole					
				 
							
					
						MRC:
						An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
					 
					
						Contact Action Stimulus:
					
					
						Increase					
				 
							
					
						MRC:
						The maximum pressure that an item will withstand without resulting in any permanent changes in the structural,mechanical,or electrical characteristics.CQJB
					 
					
						Proof Pressure:
					
					
						10.00 pounds per square inch					
				 
							
					
						MRC:
						The general configuration and relative position of the facilities provided for mounting the item.CQYJ
					 
					
						Mounting Facility Pattern:
					
					
						Four position rectangular					
				 
							
					
						MRC:
						The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
					 
					
						Nonpile-up Contact Arrangement:
					
					
						1 pole,  double throw,  one position momentary					
				 
							
					
						MRC:
						Indicates the type of terminal for providing electrical connection to the item.CSCF
					 
					
						Terminal Type:
					
					
						Connector,  receptacle					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						10.0 amperes resistive load single voltage					
				 
							
					
						MRC:
						The adjustability of the contact.CTYC
					 
					
						Contact Adjustability:
					
					
						Deactuation point adjustable,  preset and  actuation point adjustable,  preset					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						28.0 dc at sea level single voltage					
				 
							
					
						MRC:
						Indicates the type of pressure connector.CTZL
					 
					
						Pressure Connector Type:
					
					
						Gasket seal,  threaded internal single connection					
				 
							
					
						MRC:
						The type of media for which the item is designed.MEDA
					 
					
						Media For Which Designed:
					
					
						Gas					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Cylindrical w/mounting lugs					
				 
							
					
						MRC:
						A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
					 
					
						Thread Series Designator:
					
					
						Unf first threaded hole					
				 
							
					
						MRC:
						A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
					 
					
						Thread Series Designator:
					
					
						Unf second threaded hole