TXT
묘사:
Radio Frequency Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 1.220 inches and 1.280 inches
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
52 single component 2nd secondary
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
64 single component single primary
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
16 single component 1st secondary
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
0.900 inches single mounting facility single center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
0.800 inches single mounting facility single center group
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 0.980 inches and 1.020 inches
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
215.00 microhenries single component single primary
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
100.0 kilohertz single component
MRC:
Indicates the type of support on which the coil is wound.ACZP
Coil Form Type:
Solid single component
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
1.000 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
155.0 degrees celsius
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
2 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded hole single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component single primary and winding turns single component single primary
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Winding turns single component all secondary
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 2 secondary single component
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.01003 inches american wire gage single component 2nd secondary
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.01003 inches american wire gage single component single primary
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.02010 inches american wire gage single component 1st secondary
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
13160-7573710 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
9 wire lead