MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
11.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
9.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.500 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The means of attaching the item.ADJH
Mounting Method:
Portable
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Metal
MRC:
An indication of whether or not a container from which the item is completely removable in normal operable condition is provided.AFJU
Carrying Case:
Not provided
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Meter
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Alpha rays detects
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Beta rays measures
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Gamma rays detects
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Alpha rays measures
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Beta rays detects
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Gamma rays measures
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
X-rays detects
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
X-rays measures
MRC:
Indicates the type of detecting element included.AMRX
Detecting Element Type:
Ionization chamber
MRC:
An indication of whether or not the item is portable.APCB
Portability:
Portable
MRC:
The minimum and maximum amount of radiation detected per hour.APPJ
Radiation Range Per Hour:
+0.0/+25.0 roentgens
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-10.0/+10.0 at full scale
MRC:
The value of electrical potential to which an item will respond.APPP
Input Sensitivity Voltage Rating:
Not rated
MRC:
An indication of the energy dependence rating of the item.APPQ
Energy Dependence Rating:
+0.007/+2.000 mev
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
22.5