부품 정보
Underwater power cable
TXT
묘사:
Electrical Special Purpose Cable
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
125.0 degrees fahrenheit
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
1.750 inches
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
4
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
1045 all conductors
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
1/0 awg all conductors
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
30 all conductors
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Nthis cable is intended to be used underwater with a survivable depth of 120 feet of sea water. This cable must withstand an emi environment of 200 v/m; constucted in accordance with mil-c-24640 except where noted.
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper 2nd position shield braid, metallic
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper core conductor all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic cross-linked polyolefin 4th position jacket or plastic polyurethane 4th position jacket