TXT
묘사:
Flow Control Thermostat
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.125 inches
MRC:
The means of attaching the item.ADJH
Mounting Method:
Threaded
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
By-pass
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Aircraft engine oil cooler
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
Cool engine oil
MRC:
The measured distance the valve travels.AMSD
Valve Travel Distance:
0.250 inches
MRC:
Indicates the type of thermostat.AWPA
Thermostat Type:
Solid expansion
MRC:
The rated temperature at which the item starts to open.AWTM
Opening Tempurature Rating:
50.0 degrees fahrenheit
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
162.0 degrees fahrenheit
MRC:
An indication of whether or not a spring operated pressure relief is provided.AWTP
Spring Operated Pressure Relief:
Not provided
MRC:
The distance across the flats.AWTQ
Distance Across Flats:
2.125 inches
MRC:
The distance from the inside mounting surface to the valve seat.AWTR
Inside Mounting Surface To Valve Seat Distance:
2.937 inches
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Valve, temp regulating engine oil cooling, aircraft