부품 번호 73410

Oil Viscosimeter Test Bath

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards

이 제품의 과거 가격은 3293.628 and 4307.052 USD. 수량, 가용성, 상태, 리드 타임 및 품목 중단 가능성에 따라 최신 견적을 제공할 때까지 가격을 보장할 수 없습니다.

부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
73410
비무장화:
No
수명:
N/A
측정 단위:
1 EA
NIIN:
007293990
NSN
국가 주식 번호:
6630-00-729-3990 6630007293990
TXT
묘사:
Oil Viscosimeter Test Bath
INC
INC
아이템 이름 코드:
19134
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
0.0 degrees fahrenheit and 210.0 degrees fahrenheit
MRC:
Indicates the type of heating element current whether alternating,direct,or both.BBJZ
Heating Element Current Type:
Ac
MRC:
The number of alternating current phases for which the heating element is designed.BBKB
Heating Element Phase:
Single
MRC:
The cycles per second /hertz/ of alternating current for which the heating element is designed.BBKC
Heating Element Frequency In Hertz:
50.0 or 60.0
MRC:
The total value of electrical potential for which the heating element is rated,expressed in volts.BBTF
Heating Element Voltage In Volts:
115.0
MRC:
The rated power the heating element can safely consume or provide,measured in watts.BBTG
Heating Element Wattage In Watts:
900.0
MRC:
The means by which the item is heated.BDWT
Heating Method:
Electrical
MRC:
Indicates the type of heating element provided.BDXJ
Heating Element Type:
Lagless
MRC:
The number of elements in the item.BHHK
Element Quantity:
3
MRC:
The number of pipette(s) for which the item is designed.BNHW
Err Default:
Err default
MRC:
The number of pipette(s) for which the item is designed.BNHW
Pipette Quantity For Which Designed:
3
MRC:
The liquid used to indicate the operating temperature of the item.BNHX
Err Default:
Err default
MRC:
The liquid used to indicate the operating temperature of the item.BNHX
Operating Tempurature Indicating Liquid:
White oil
MRC:
An indication of whether or not a constant temperature control is included.BNHY
Err Default:
Err default
MRC:
An indication of whether or not a constant temperature control is included.BNHY
Constant Tempurature Control:
Included
MRC:
An indication of the accuracy of an item.BNHZ
Accuracy Rating:
-0.50 degrees fahrenheit and 0.50 degrees fahrenheit
MRC:
An indication of whether or not a liquid circulator is included.BNJB
Err Default:
Err default
MRC:
An indication of whether or not a liquid circulator is included.BNJB
Liquid Circulator:
Included
MRC:
The length of a straight line which passes through the center of the reservoir,and terminates at the inside circumference.BNLZ
Err Default:
Err default
MRC:
The length of a straight line which passes through the center of the reservoir,and terminates at the inside circumference.BNLZ
Reservoir Inside Diameter:
16.000 inches
MRC:
A measurement between specified inside points on the reservoir,in distinction from height.BNMC
Err Default:
Err default
MRC:
A measurement between specified inside points on the reservoir,in distinction from height.BNMC
Reservoir Inside Depth:
12.000 inches
MRC:
The design of the pipette(s) accommodated.BNMF
Err Default:
Err default or err default
MRC:
The design of the pipette(s) accommodated.BNMF
Accommodated Pipette Design:
Ostwald or ubbelohde

{lang[cimilar]} Oil Viscosimeter Test Bathes

« Chemical Analysis Instruments {lang[catalog]}
지금 비교»
맑다 | 숨기다