TXT
묘사:
Oil Viscosimeter Test Bath
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
0.0 degrees fahrenheit and 210.0 degrees fahrenheit
MRC:
Indicates the type of heating element current whether alternating,direct,or both.BBJZ
Heating Element Current Type:
Ac
MRC:
The number of alternating current phases for which the heating element is designed.BBKB
Heating Element Phase:
Single
MRC:
The cycles per second /hertz/ of alternating current for which the heating element is designed.BBKC
Heating Element Frequency In Hertz:
50.0 or 60.0
MRC:
The total value of electrical potential for which the heating element is rated,expressed in volts.BBTF
Heating Element Voltage In Volts:
115.0
MRC:
The rated power the heating element can safely consume or provide,measured in watts.BBTG
Heating Element Wattage In Watts:
900.0
MRC:
The means by which the item is heated.BDWT
Heating Method:
Electrical
MRC:
Indicates the type of heating element provided.BDXJ
Heating Element Type:
Lagless
MRC:
The number of elements in the item.BHHK
Element Quantity:
3
MRC:
The number of pipette(s) for which the item is designed.BNHW
Err Default:
Err default
MRC:
The number of pipette(s) for which the item is designed.BNHW
Pipette Quantity For Which Designed:
3
MRC:
The liquid used to indicate the operating temperature of the item.BNHX
Err Default:
Err default
MRC:
The liquid used to indicate the operating temperature of the item.BNHX
Operating Tempurature Indicating Liquid:
White oil
MRC:
An indication of whether or not a constant temperature control is included.BNHY
Err Default:
Err default
MRC:
An indication of whether or not a constant temperature control is included.BNHY
Constant Tempurature Control:
Included
MRC:
An indication of the accuracy of an item.BNHZ
Accuracy Rating:
-0.50 degrees fahrenheit and 0.50 degrees fahrenheit
MRC:
An indication of whether or not a liquid circulator is included.BNJB
Err Default:
Err default
MRC:
An indication of whether or not a liquid circulator is included.BNJB
Liquid Circulator:
Included
MRC:
The length of a straight line which passes through the center of the reservoir,and terminates at the inside circumference.BNLZ
Err Default:
Err default
MRC:
The length of a straight line which passes through the center of the reservoir,and terminates at the inside circumference.BNLZ
Reservoir Inside Diameter:
16.000 inches
MRC:
A measurement between specified inside points on the reservoir,in distinction from height.BNMC
Err Default:
Err default
MRC:
A measurement between specified inside points on the reservoir,in distinction from height.BNMC
Reservoir Inside Depth:
12.000 inches
MRC:
The design of the pipette(s) accommodated.BNMF
Err Default:
Err default or err default
MRC:
The design of the pipette(s) accommodated.BNMF
Accommodated Pipette Design:
Ostwald or ubbelohde