부품 정보
J23 singles are size 20 awg (19x32)per mil-w-16878/17, 14 twisted pairs are awg size 24 (19x36)per mil-w-16878/17 and outer jacket of polychloroprene is applied in two layers with a reinforcement between layers.
TXT
묘사:
Electrical Special Purpose Cable
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-54.0 degrees celsius and 71.0 degrees celsius
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
1.085 inches
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
57
MRC:
The specification, standard, drawing, or similar instrument that specifies the individual color coding under which the item is identified by an alphabetic and/or numeric reference number.includes the commercial and government entity (cage) code of the entity controlling the instrument.AWXS
Color Coding Document:
720423-05869 drawing
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
20 singles and 14 twisted pair and 2 twin-axial parallel and 2 coaxial
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
600.0 root mean square (rms) operating voltage all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Rubber polychloroprene 5th position jacket cable
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Mil-c-13777 military specification single material response 5th position jacket cable