MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.000 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.320 inches
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
1
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+125.0 degrees celsius
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
3
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
50.000 volts
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Any acceptable
MRC:
The plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the item and its location.ANNR
Surface Treatment And Location:
Any acceptable
MRC:
The total oppositon (resistive and reactive) which the item offers to the input flow of alternating current.ANSL
Input Impedance Rating:
200.000 ohms
MRC:
The total opposition (resistive and reactive) which the item offers to the output flow of alternating current.ANSR
Output Impedance Rating:
200.000 ohms
MRC:
A measurement between specified points on a body in distinction from height.ARBR
Body Depth:
0.320 inches
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Terminal
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
0.500
MRC:
The means by which the signal is delayed.BZWM
Signal Delay Method:
Inductance
MRC:
The time delay of each section of an item.CCDQ
Section Delay Time:
10.000 nanoseconds single section
MRC:
The rated time required for the pulse to rise.CCDX
Pulse Rise Time Rating:
3.0 nanoseconds
MRC:
Indicates the type and number of terminals for providing electrical connection.CCFF
Terminal Type And Quantity:
3 wire leads