MRC:
A recording of the physical,functional,and performance characteristics for an item of supply.TEXT
General Description:
Max output control signal capabili type 512 channels; receives zone (monitor point) status changes on map data bus operating at 640 baud; generates 5 v positive-going 0.5 millisec pulse corresponding to a zone in which status has changed from secure to alarm, to control associated video switching matrix that causes automatic monitor display of video from cctv camer (s) covering alarmed zone; oper pwr rqmts 115/230 vac, 50/60 hz, single ph, 75 watts; o/a dims 19.0 in. W; 10.5 in. H; 15.0 in. D; rack mounted in fixed ground installation; special feature: four-hour battery backup with automatic switching and recharging