TXT
묘사:
Alternating Current Motor
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
10.750 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
16.380 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
10.500 inches
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Dripproof protected-45 deg
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The means by which the current is rated.BKPB
Current Rating Method:
Load
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Nema
MRC:
A designation indicating the frame size by which the item is identified.CNMM
Frame Size Designation:
213tc
MRC:
The amount of electrical energy that can be dissipated.CNXS
Power Rating:
7.500 horsepower output
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
3.120 inches first end
MRC:
The distance between the center of the shaft to the mounting surface.CWDM
Shaft Center To Mounting Surface Distance:
5.250 inches first end
MRC:
The nominal center to center distance between the mounting facilities parallel to the length.CWDT
Center To Center Distance Between Mounting Facilities Parallel To Length:
5.500 inches
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
50.0 ambient degrees celsius
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
1760.0 single full load
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
8.500 inches
MRC:
The nominal center to center distance between the mounting facilities parallel to the height.CWGD
Center To Center Distance Between Mounting Facilities Parallel To Height:
5.250 inches
MRC:
The amount of current for which an item is rated,expressed in amperes.CWGL
Current Rating In Amps:
9.300 single input
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
460.0 line to line single input
MRC:
The number of alternating current phases.FAAZ
Phase:
Three input
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 input