부품 정보
Push button thermal circuit breaker, 15a
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Boat, riverine, patrol, 38foot, 38rp0701, 702, 703, 704, 705, 706, 707, 708, 709, 710
MRC:
The maximum current load that each pole is rated to carry continuously.CPLM
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes dc single location
MRC:
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.CPRG
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
2500.0 dc single location
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Boot thread 3/8 in-27; maximum voltage rating 28v dc; boot material uv resistant silicone rubber; operating temp -10 degrees c to +60 degrees c; boot thread material nickel-plated brass; thermal trip, manual push button reset only
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Trip free design cannot be held on during fault current condition; igniton protected safe for aboard gasoline powered boats; ideal for 24 hour circuit protection