MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 0.840 inches and 0.900 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
Between 0.177 inches and 0.197 inches
MRC:
The temperature of the medium surrounding an item at which it can be operated continuously at full rated power.AEHY
Ambient Tempurature At Full Rated Power:
400.0 degrees fahrenheit
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
400.0 degrees fahrenheit
MRC:
The time required for the temperature of an item to change 63.2 percent of the difference between its initial and final body temperature when subjected to a temperature change under zero power conditions,expressed in seconds.AEJA
Thermal Time Constant In Seconds:
10.0
Probe Diameter:
Between 0.350 inches and 0.410 inches
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
Between 1.240 inches and 1.260 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The dc resistance value measured with a power dissipation low enough that any further decrease in power will result in not more than 0.1 percent change in resistance.CQWD
Zero Power Resistance:
4.175 kilohms
MRC:
The limits of permissible variation in the electrical resistance value of an item from its rated zero power resistance,expressed in percent at reference temperature.CRQJ
Zero Power Resistance Tolerance In Percent At Reference Temp:
-2.0 to 2.0
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Probe, flange mounting
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 threaded stud