MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
2.830 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.820 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.570 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Relay
MRC:
The quantity and combination/s/ of the basic contact forms,in the order of assemblage,which make up the switching structure of the item.AFTL
Contact Form Arrangement:
4c
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four tapped holes on back plate
MRC:
Indicates the type of action provided.AMWM
Action Type:
Time delay
MRC:
Indicates the type of relay/s/ provided.APCL
Relay Type:
Time delay
MRC:
Indicates the type of current used with the contact/s/.APFX
Contact Current Type:
Ac
MRC:
The maximum voltage rating at which the item is designed to operate,expressed in volts.APFY
Maximum Voltage Rating In Volts:
120.0
MRC:
The amount of current at maximum rated voltage for which the item is designed.APGW
Current Rating At Maximum Rated Voltage:
10.0 amperes resistive
MRC:
The amount of voltage for which the item is designed to withstand at the maximum rated current.APGY
Voltage Rating At Maximum Rated Current:
120.0 volts
MRC:
Indicates the type of current for which the coil is designed.APGZ
Coil Current Type:
Ac
MRC:
The amount of operating voltage,expressed in volts.APHA
Operating Voltage In Volts:
Between 102.0 and 132.0
MRC:
The designation that identifies the schematic diagram of the electrical configuration of a switch.APLQ
Switch Contact Arrangement:
4spdt
MRC:
The maximum voltage rating at which the contact is rated,expressed in volts.APLS
Contact Maximum Voltage Rating In Volts:
120.0
MRC:
The amount of time required for tripping the item,expressed in seconds.APMG
Tripping Time In Seconds:
2.0
MRC:
The continuous load percentage for the specified tripping time of the item.APMH
Err Default:
Err default
MRC:
The continuous load percentage for the specified tripping time of the item.APMH
Continuous Load Percentage Per Specificationified Tripping Action Time:
50.0
MRC:
The designation that identifies the schematic diagram of the contact configuration.CPWK
Contact Arrangement:
4spdt