TXT
				
				
					묘사:
				
				
					Rota Electro-mechanical Actuator				
			 
			
							
										
					
						MRC:
						Indicates the type of terminals for providing electrical connection to the item.AARB
					 
					
						Terminal Type:
					
					
						Connector					
				 
							
					
						MRC:
						A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
					 
					
						Tempurature Rating:
					
					
						-65.0 degrees fahrenheit and 225.0 degrees fahrenheit					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
					 
					
						Body Diameter:
					
					
						2.250 inches 					
				 
							
					
						MRC:
						Indicates the type of current whether alternating,direct,or both.ACDC
					 
					
						Current Type:
					
					
						Dc					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						Between 8.370 inches and 8.620 inches 					
				 
							
					
						MRC:
						The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
					 
					
						Environmental Protection:
					
					
						Pressure proof					
				 
							
					
						MRC:
						The speed of the drive shaft required to produce the rated capacity of an item,expressed in revolutions per minute.AEQC
					 
					
						Operating Speed At Rated Capacity In Rpm:
					
					
						15.0					
				 
							
					
						MRC:
						The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
					 
					
						Shaft Rotation Direction:
					
					
						Clockwise and counterclockwise					
				 
							
					
						MRC:
						Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
					 
					
						Drive Type:
					
					
						Direct					
				 
							
					
						MRC:
						The working period under which the item was designed to operate.AKPS
					 
					
						Duty Cycle:
					
					
						Intermittent					
				 
							
					
						MRC:
						The electrical current rating,expressed in amperes.AMPS
					 
					
						Current Rating In Amps:
					
					
						2.0					
				 
							
					
						MRC:
						The means by which the braking action is applied.ATWS
					 
					
						Braking Method:
					
					
						Electric					
				 
							
					
						MRC:
						The measurement of rotation,expressed in degrees.AWQL
					 
					
						Rotation In Deg:
					
					
						90.0 					
				 
							
					
						MRC:
						An indication of whether or not a limit switch control is included.AWQN
					 
					
						Limit Switch Control:
					
					
						Included					
				 
							
					
						MRC:
						An indication of whether or not a manual override is included.AWQR
					 
					
						Manual Override:
					
					
						Not included					
				 
							
					
						MRC:
						An indication of the rotation of the angular shaft.AWTZ
					 
					
						Angular Shaft Rotation:
					
					
						Limited					
				 
							
					
						MRC:
						The maximum operating on time and the minimum off time for a complete cycle of an item.AYEK
					 
					
						Intermittent Operation Duty Cycle:
					
					
						1.0 seconds  on and 7.0 seconds  off					
				 
							
					
						MRC:
						The total electrical voltage.ELEC
					 
					
						Voltage In Volts:
					
					
						18.0 and 32.0					
				 
							
					
						MRC:
						The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
					 
					
						Fsc Application Data:
					
					
						Aircraft air conditioning, heating and pressurization equipment