TXT
묘사:
Flow Rate Indicating Meter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.156 inches
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
0il
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Threaded
MRC:
An indication of whether or not an integral safety device is included.AHZU
Integral Relief Valve:
Not included
MRC:
Indicates the design type of the item.APGF
Design Type:
Glass
MRC:
Indicates the type of unit.APQB
Unit Type:
Mounted
MRC:
The number of scales on the item.APSJ
Scale Quantity:
1
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Threaded
MRC:
An indication of the marking(s) on the scale.ASTW
Scale Marking:
Gal per min
MRC:
Indicates the type of scale.ATEQ
Scale Type:
Direct capacity reading
MRC:
The number of floats provided.AWAE
Float Quantity:
1
MRC:
The means of attaching the item.AXGY
Mounting Method:
Direct line
MRC:
The minimum and maximum markings on a dial scale.BHBY
Dial Scale Marking Range:
+2.0 to 30.0
MRC:
Designates the size of the outlet connection included on the item.BHCM
Outlet Connection Size:
0.750 in. Npt
MRC:
Indicates the type of float used.BHSQ
Float Type:
Guided
MRC:
Indicates the type of guide provided.BMHW
Guide Type:
Solid rod
MRC:
An indication of whether or not an integral heat source is included.BNHN
Integral Heat Source:
Not included
MRC:
The maximum working pressure at which an item is designed to operate.BPHD
Maximum Working Pressure:
3000.0 pounds per square inch
MRC:
Designates the size of the inlet connection included on the item.CPZD
Inlet Connection Size:
0.750 in. Npt
MRC:
An indication of whether or not a dial scale reference pointer is included.CPZK
Dial Scale Reference Pointer:
Not included
MRC:
An indication of whether or not a spinning float is included.CPZM
Spinning Float:
Not included
MRC:
An indication of whether or not an integral pulsation dampener is included.CPZN
Integral Pulsation Dampener:
Not included
MRC:
The inlet connection position for which the item is designed.CPZP
Inlet Connection Position For Which Designed:
Horizontal
MRC:
Indicates the type of inlet connection device provided.CPZQ
Inlet Connection Device Type:
Stationary
MRC:
The outlet connection position for which the item is designed.CPZR
Outlet Connection Position For Which Designed:
Horizontal
MRC:
Indicates the type of outlet connection device provided.CPZS
Outlet Connection Device Type:
Stationary
MRC:
An indication of whether or not an alarm signal is included.CPZT
Alarm Signal:
Not included