TXT
묘사:
Centrifugal Pump Unit
MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
3
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Water, salt
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
1
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
430.0 gallons per minute
MRC:
The sum of the total discharge head and the total suction lift.AHYX
Total Head:
150.000 feet
MRC:
The speed of the item required to produce its rated capacity.AHYZ
Operating Speed At Rated Capacity:
3550.0 revolutions per minute
MRC:
The number of impellers incorporated in the centrifugal pump.AHZF
Centrifugal Pump Impeller Quantity:
1
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
28.9
MRC:
The rated power of the prime mover.CSYL
Prime Mover Power Rating:
25.000 horsepower
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
440.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three