부품 정보
Inavy: controller ac magnetic sze 2
MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
Dripproof
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
26.120 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
18.120 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
440.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Magnetic
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Controller a.C. Magnetic size 2
MRC:
The number of fuses the item is designed to accommodate /including spares/.AGUE
Fuse Accommodation Quantity:
6
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Six .531 inch diameter mounting holes on 24.00 x begining at upper left 1.81 x 7.25 x 7.25 inch mounting centers
MRC:
An indication of the characteristic of the operating voltage.ANCN
Operating Voltage Characteristic:
Full
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
25.000
MRC:
The voltage required to actuate the item.ANDE
Actuator Voltage:
440.0 ac
MRC:
The value of current for which the fuse is rated,expressed in amperes.ANDG
Fuse Current Rating In Amps:
10.0
MRC:
The temperature of the medium surrounding an item at which it can be operated.ANDX
Ambient Temp:
50.0 degrees celsius
MRC:
Indicates the type of control.AQZF
Control Type:
Local or remote
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Circuit protection fuse
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Controller nameplate no.: 6962ed3672a1; n2000 hand held programmer, p/nn2000hhp, n2000 current range 9 to 32a; controller weight: 111 lbs (actl), repair parts (boxed): 12 lbs (est); type: across the line; shockproofness: grade a, class 1 of mil-s-901; no exceptions to military spec. Mil-c-2212
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0