TXT
묘사:
Electrical Receptacle Connector
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight edge type w/mounting flange
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.724 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.681 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.333 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
Between 0.111 inches and 0.121 inches
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
Between 3.401 inches and 3.411 inches
Board Accommodated Length:
2.948 inches single board and 2.958 inches single board
MRC:
The number of mating ends provided with the item which are designed to accommodate another connector.AFQW
Mating End Quantity:
1
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the contact position/s/.AFQX
Contact Position Arrangement Style:
2 rows of independent contacts inserted board single mating end
MRC:
An indication of whether or not the contact(s) is removable.AFQZ
Contact Removability:
Nonremovable single mating end single contact grouping
MRC:
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.AFRC
Contact Maximum Current Rating In Amps:
5.0 single mating end single contact grouping
MRC:
The maximum alternating current potential that may be applied continuously to the contact without damage,expressed in volts.AFRD
Contact Maximum Ac Voltage Rating In Volts:
1800.0 single mating end single contact grouping
MRC:
The means used to prevent mismating or cross plugging of contacts.AFRN
Polarization Method:
Fixed inter-contact
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
Back single mating end single contact grouping
MRC:
The chemical compound or mechanical mixture properties of which the contact is fabricated.CQTZ
Contact Material:
Copper alloy single mating end single contact grouping
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the contact surface(s) and cannot be wiped off.CQYH
Contact Surface Treatment:
Gold single mating end single contact grouping
MRC:
The chemical compound or mechanical mixture properties of which the insert is fabricated.CQZG
Insert Material:
Plastic diallyl phthalate single mating end
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Tab, solder lug single mating end single contact grouping
MRC:
The number of contacts included with the item which provides electrical connection.CXCG
Included Contact Quantity:
18 single mating end single contact grouping
MRC:
Indicates the type of contact(s) included with the item.CXCL
Included Contact Type:
Bifurcated spring single mating end single contact grouping
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Contact surfaces gold
MRC:
An indication of the precious material contained in the item,and the amount per a measurement scale.PMWT
Precious Material And Weight:
0.018 gold grains, troy
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Gold
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
10001-695226 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)