부품 정보
One delayed spdt, one instantaneous spdt
TXT
묘사:
Electromagnetic Relay
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
E/i 688250-1, cg-25 oily water separator
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.CRNG
Nonpile-up Main Contact Arrangement:
2 pole, double throw, one position momentary
MRC:
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
Time Delay:
0.05 seconds adjustable operate time and 180.00 hours adjustable operate time
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
3.0 amperes ac resistive load