TXT
묘사:
Immersion Thermocouple
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABXG
Overall Length:
Between 7.687 inches and 7.891 inches
MRC:
The length of a straight line which passes through the center of a mounting bolt circle,and terminates at the circumference.AFFL
Mounting Bolt Circle Diameter:
Between 2.140 inches and 2.160 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+1000.0/+1975.0 degrees fahrenheit
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
F-100 engines
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 flange
MRC:
A measurement of the longest dimension of the immersed portion of the item,in distinction from width.BKBW
Immersion Length:
Between 2.557 inches and 2.567 inches
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Spring loaded thermocouple; aluminide coated; has two type k thermocouples; mounting holes in flange are 0.220 in dia
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Thermocouple is a dual element immersion thermocouple designed for use in the pratt & whitney f 100 engines, location is the front turbine inlet
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Nickel alloy thermocouple wire
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
Pratt & whitney drawing 4087911 and rosemount drawing 6837
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 terminal block w/screws